Effect of air inlet velocity on air water harvester with small tube evaporator

Breadcrumb

  • Home
  • Effect of air inlet velocity on air water harvester with small tube evaporator

Mirmanto Mirmanto *, Anang Suriatman and Made Nuarsa

Department of Mechanical Engineering, Faculty of Engineering, University of Mataram, Jl. Majapahit no.62, Mataram, West Nusa Tenggara, 83125, Indonesia.
 
 
Research Article
Global Journal of Engineering and Technology Advances, 2025, 23(03), 200-208.
Article DOI: 10.30574/gjeta.2025.23.3.0195
DOI url: https://doi.org/10.30574/gjeta.2025.23.3.0195
Received on 28 March 2025; revised on 11June 2025; accepted on 13June 2025
 
 
During the dry season, parts of Indonesia experience drought and clean water crises.  One of the efforts to obtain clean water was by presenting a machine called air-water harvester.  The amount of water mass produced depended on several variables such as RH, intake air temperature, type of condensing unit, intake air velocity and engine power.  This study aims to determine the performance of the air-water harvester at various inlet air velocities.  The dependent variables expected were the mass of water produced, COP, and the amount of heat absorbed from the air.  This research was carried out experimentally with the working fluid refrigerant R134a.  The compressor used was a rotary type 1 PK compressor.  This study varied the air velocity entering the evaporator, namely 1.5 m/s, 3 m/s and 4.5 m/s.  The results showed that the highest mass of water was 0.728 kg.  Meanwhile, the highest COP was 5.13, and the total heat transfer rate absorbed by the evaporator was 160.38 W. All were obtained at the air velocity of 4.5 m/s.
 
Air-water harvester;Inlet air velocity; Water mass; Heat transfer rate; COP
 
https://gjeta.com/sites/default/files/fulltext_pdf/GJETA-2025-0195.pdf

Preview Article PDF

Mirmanto Mirmanto, Anang Suriatman and Made Nuarsa. Effect of air inlet velocity on air water harvester with small tube evaporator. Global Journal of Engineering and Technology Advances, 2025, 23(3), 200-208. Article DOI: https://doi.org/10.30574/gjeta.2025.23.3.0195

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.