Monitoring of structural health and safety of Flores hall and Valencia hall: Inputs for repair, renovation, and retrofitting phase II

Breadcrumb

  • Home
  • Monitoring of structural health and safety of Flores hall and Valencia hall: Inputs for repair, renovation, and retrofitting phase II

Cecilia Angeles Geronimo *, Radger Teddy Lee Manuel and Merricris Uson Pangilinan

Department of Civil Engineering, College of Engineering, Bulacan State University, City of Malolos, Bulacan, Philippines, 3000.
 
Research Article
Global Journal of Engineering and Technology Advances, 2023, 15(02), 073-090.
Article DOI: 10.30574/gjeta.2023.15.2.0088
DOI url: https://doi.org/10.30574/gjeta.2023.15.2.0088
Received on 05 April 2023; revised on 15 May 2023; accepted on 18 May 2023
 
The evaluation of structures is imperative as these structures age and exposed to different external and internal stresses and resistances. The strength of any structure inclusive of its structural components, can be determined from its health and safety. This study aimed to evaluate the structural health and safety of Flores Hall and Valencia Hall through the use of Non-Destructive Test specifically the Rebound Hammer Test and consequently propose Preventive Maintenance Management Plan. The researchers conducted non-destructive Rebound Hammer test to the structural components such as beams, bleachers, columns, and slabs of the two Halls. The results of the Rebound Hammer test were automatically produced, tabulated, and analyzed. For Flores Hall, most of the columns in the ground floor have existing condition of structurally sound which means above with the allowable compressive strength while in the second floor some of the columns have existing conditions of moderate, considerable, and major distress which were below the allowable compressive strength; in the beams and slabs, some of the grid lines have existing condition of structurally sound which were above the allowable compressive strength while majority of the grid lines have existing conditions of moderate, considerable, and major distress which were below with the allowable compressive strength. All the grid lines of the bleachers in Valencia Hall when tested by Hammer Rebound equipment yielded compressive strength above the allowable compressive strength of 28 MPa. Also, majority of the columns in Valencia Hall have existing condition of structurally sound which were above the allowable compressive strength but some of the columns have existing condition of moderate, and considerable distress which were below the allowable compressive strength. Furthermore, for the beams tested, all have existing condition of structurally sound which means above the allowable compressive strength. The Non-Destructive Test through the use of Hammer Rebound Test equipment to monitor the structural health and safety of Flores Hall and Valencia Hall yielded data in terms of the existing conditions of the beams, columns, slabs, and bleachers. The results of the Hammer Rebound test revealed the average compressive strength per grid or grid line of the structural components which show if the structural component complied with the allowable compressive strength. The proposed Preventive Maintenance Management Plan may be used to systematically implement the monitoring of structural health and safety of the Flores Hall and Valencia Hall and provide a safe structure where administrative officials, faculty members, students, and other stakeholders can perform their works and transactions.
 
Structural health and safety; Concrete beams; Bleachers; Columns; Slabs; Non-destructive test
 
https://gjeta.com/sites/default/files/fulltext_pdf/GJETA-2023-0088.pdf

Preview Article PDF

Cecilia Angeles Geronimo, Radger Teddy Lee Manuel and Merricris Uson Pangilinan. Monitoring of structural health and safety of Flores hall and Valencia hall: Inputs for repair, renovation, and retrofitting phase II. Global Journal of Engineering and Technology Advances, 2023, 15(2), 073-090. Article DOI: https://doi.org/10.30574/gjeta.2023.15.2.0088

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content

          

 

Copyright © 2026 Global Journal of Engineering and Technology Advances - All rights reserved

Developed & Designed by VS Infosolution