Home
Global Journal of Engineering and Technology Advances
International Peer reviewed Engineering Journal || Crossref DOI || Impact Factor 8.6 || ISSN: 2582-5003

Main navigation

  • Home
    • Journal Information
    • Editorial Board Members
    • Reviewer Panel
    • Abstracting and Indexing
    • Journal Policies
    • Our CrossMark Policy
    • Publication Ethics
    • Issue in Progress
    • Current Issue
    • Past Issues
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Join Editorial Board
    • Join Reviewer Panel
  • Contact us
  • Downloads

Research & review articles are invited for publication in November 2026 (Vol. 29, Issue 2) || Submission: up to 28th November || Editorial decision: within 48 hrs.

SEVEN-CLASS LOWER-LIMB ACTIVITY RECOGNITION USING THREE-CHANNEL SEMG

Breadcrumb

  • Home
  • SEVEN-CLASS LOWER-LIMB ACTIVITY RECOGNITION USING THREE-CHANNEL SEMG

Javier Rodríguez-Herrejón *, Enrique Reyes-Archundia, Jose A. Gutiérrez-Gnecchi, Marco V. Chávez-Báez and Jonathan A. Sanchez Trujillo

Division for Postgraduate Studies, Technological Institute of Morelia, Morelia, Mexico.
* Corresponding Author
ORCID Details
Javier Rodríguez-Herrejón: https://orcid.org/0000-0002-9767-425X
Enrique Reyes-Archundia: https://orcid.org/0000-0003-3374-0059
Jose A. Gutiérrez-Gnecchi: https://orcid.org/0000-0001-7898-604X
Marco V. Chávez-Báez: https://orcid.org/0000-0002-6294-2074

Research Article

Global Journal of Engineering and Technology Advances, 2026, 29(02), 001–011

Article DOI: 10.30574/gjeta.2026.29.2.0313

DOI url: https://doi.org/10.30574/gjeta.2026.29.2.0313

Received on 22 September 2026; revised on 29 October 2026; accepted on 31 October 2026

Three-channel sEMG recordings may contain different signatures of lower-limb activity, but separating movements is less straightforward when they recruit some of the same muscles. We examined this problem in seven right-leg activities using the conditioned envelopes recorded over rectus femoris, vastus lateralis, and semitendinosus. The experiment comprised five repeated movements and two sustained postures, each recorded for 40 s during one session with a 25-year-old participant without amputation. We divided the recordings into 300-ms windows with 60% overlap, extracted seven time-domain descriptors, and used them in a support vector machine (SVM). The stored test matrix contains 464 windows and 401 correct assignments, corresponding to 86.42% accuracy. The findings describe the discrimination achieved with the selected channels and indicate aspects of electrode placement and cycle labeling that warrant further testing.

Lower-limb activity recognition; EMG; Support Vector Machine; Movement classification.

https://gjeta.com/sites/default/files/fulltext_pdf/GJETA-2026-0313.pdf

Preview Article PDF

Javier Rodríguez-Herrejón, Enrique Reyes-Archundia, Jose A. Gutiérrez-Gnecchi, Marco V. Chávez-Báez and Jonathan A. Sanchez Trujillo. SEVEN-CLASS LOWER-LIMB ACTIVITY RECOGNITION USING THREE-CHANNEL SEMG. Global Journal of Engineering and Technology Advances, 2026, 29(02), 001–011. Article DOI: https://doi.org/10.30574/gjeta.2026.29.2.0313.

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.