Home
Global Journal of Engineering and Technology Advances
International Peer reviewed Engineering Journal || Crossref DOI || Impact Factor 8.6 || ISSN: 2582-5003

Main navigation

  • Home
    • Journal Information
    • Editorial Board Members
    • Reviewer Panel
    • Abstracting and Indexing
    • Journal Policies
    • Our CrossMark Policy
    • Publication Ethics
    • Issue in Progress
    • Current Issue
    • Past Issues
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Join Editorial Board
    • Join Reviewer Panel
  • Contact us
  • Downloads

Research & review articles are invited for publication in October 2026 (Vol. 29, Issue 1) || Submission: up to 28th October || Editorial decision: within 48 hrs.

Classification and comparison of glaucoma detection methods in retinal fundus images using SVM and U-Net2

Breadcrumb

  • Home
  • Classification and comparison of glaucoma detection methods in retinal fundus images using SVM and U-Net2

Aaron García-Campos, Javier Rodríguez-Herrejón *, Enrique Reyes-Archundia, Arturo Mendez-Patiño and Jose A. Gutiérrez-Gnecchi

Division for Postgraduate Studies, Technological Institute of Morelia, Morelia, Mexico.
 
Research Article
Global Journal of Engineering and Technology Advances, 2025, 22(03), 155-164.
Article DOI: 10.30574/gjeta.2025.22.3.0070
DOI url: https://doi.org/10.30574/gjeta.2025.22.3.0070
Received on 11 February 2025; revised on 20 March 2025; accepted on 22 March 2025
 
In medical image processing, early detection of eye diseases like glaucoma is crucial to prevent blindness. This study evaluates two deep learning models—Support Vector Machine and U-Net—for classifying retinal fundus images to improve glaucoma detection. Using 316 images from "The Brazil Glaucoma Database," the study applied various preprocessing techniques such as resizing, grayscale conversion, and edge enhancement. Optical disc and cup segmentation was achieved with Hough transform and circular masking. The SVM model outperformed U-Net, achieving 95% accuracy compared to U-Net's 88%. SVM showed better precision, recall, and F1-scores, making it more reliable for distinguishing between normal and glaucoma images. While U-Net had strong recall for glaucoma detection, its lower precision and accuracy indicate room for improvement. Future work should focus on refining U-Net to enhance its precision and overall performance.
 
Retinal Fundus; Glaucoma; Digital Image Processing; Svm; U-Net
 
https://gjeta.com/sites/default/files/fulltext_pdf/GJETA-2025-0070.pdf

Preview Article PDF

Aaron García-Campos, Javier Rodríguez-Herrejón, Enrique Reyes-Archundia, Arturo Mendez-Patiño and Jose A. Gutiérrez-Gnecchi. Classification and comparison of glaucoma detection methods in retinal fundus images using SVM and U-Net2. Global Journal of Engineering and Technology Advances, 2025, 22(3), 155-164. Article DOI: https://doi.org/10.30574/gjeta.2025.22.3.0070

Copyright © Author(s). All rights reserved. This article is published under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, sharing, adaptation, distribution, and reproduction in any medium or format, as long as appropriate credit is given to the original author(s) and source, a link to the license is provided, and any changes made are indicated.


All statements, opinions, and data contained in this publication are solely those of the individual author(s) and contributor(s). The journal, editors, reviewers, and publisher disclaim any responsibility or liability for the content, including accuracy, completeness, or any consequences arising from its use.

Get Certificates

Get Publication Certificate

Download LoA

Check Corssref DOI details

Issue details

Issue Cover Page

Editorial Board

Table of content

          

 

Copyright © 2026 Global Journal of Engineering and Technology Advances - All rights reserved

Developed & Designed by VS Infosolution